Schneider ATV630D11N4

$ 619,00 Request exact price

Terms of sale:

  • Done Price Without Shipping:
    Our prices are listed without shipping costs. Shipping charges will be calculated and added during checkout based on your location and preferred shipping method.
  • Done Price Variability:
    Please note that prices are not fixed and may change due to factors such as market fluctuations, supplier costs, or promotional offers.
  • Done Worldwide Delivery:
    We offer delivery to almost any country worldwide. During checkout, you can select your country for shipping options and associated costs.
  • Check Mark These terms ensure transparency and flexibility in pricing and shipping options for our customers across the globe.
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
Category:

Description

Main
Range of productAltivar Process ATV600
Product or component typeVariable speed drive
Product specific applicationProcess and utilities
Device short nameATV630
variantStandard version
Product destinationAsynchronous motors
Synchronous motors
EMC filterIntegrated with 50 m conforming to EN/IEC 61800-3 category C2
Integrated with 150 m conforming to EN/IEC 61800-3 category C3
IP degree of protectionIP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529
[Us] rated supply voltage380…480 V
Degree of protectionUL type 1 conforming to UL 508C
Type of coolingForced convection
Supply frequency50…60 Hz – 5…5 %
[Us] rated supply voltage380…480 V – 15…10 %
Motor power kW11 kW (normal duty)
7.5 kW (heavy duty)
Motor power hp15 hp normal duty
10 hp heavy duty
Line current19.8 A at 380 V (normal duty)
17 A at 480 V (normal duty)
14.1 A at 380 V (heavy duty)
12.5 A at 480 V (heavy duty)
Prospective line Isc50 kA
Apparent power14.1 kVA at 480 V (normal duty)
10.4 kVA at 480 V (heavy duty)
Continuous output current23.5 A at 4 kHz for normal duty
16.5 A at 4 kHz for heavy duty
Maximum transient current25.9 A during 60 s (normal duty)
24.8 A during 60 s (heavy duty)
Asynchronous motor control profileConstant torque standard
Optimized torque mode
Variable torque standard
Synchronous motor control profilePermanent magnet motor
Synchronous reluctance motor
Speed drive output frequency0.1…500 Hz
Nominal switching frequency4 kHz
Switching frequency2…12 kHz adjustable
4…12 kHz with derating factor
Safety functionSTO (safe torque off) SIL 3
Discrete input logic16 preset speeds
communication port protocolModbus TCP
Ethernet
Modbus serial
Option cardSlot A: communication module, Profibus DP V1
Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Complementary
Mounting modeWall mount
Network number of phases3 phases
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage<= power supply voltage
Permissible temporary current boost1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
Motor slip compensationAdjustable
Can be suppressed
Not available in permanent magnet motor law
Automatic whatever the load
Acceleration and deceleration rampsLinear adjustable separately from 0.01…9999 s
physical interfaceEthernet
2-wire RS 485
Braking to standstillBy DC injection
Protection typeThermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Transmission rate10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolutionDisplay unit: 0.1 Hz
Analog input: 0.012/50 Hz
Transmission frameRTU
Electrical connectionControl: removable screw terminals 0.5…1.5 mm²/AWG 20…AWG 16
Motor: screw terminal 6…10 mm²/AWG 10…AWG 8
Line side: screw terminal 6 mm²/AWG 10
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serial
Data format8 bits, configurable odd, even or no parity
type of polarizationNo impedance
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus serial
Method of accessSlave Modbus TCP
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Width171 mm
Height409 mm
Depth233 mm
Net weight7.7 kg
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2 voltage analog input: – 10…10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Discrete input number8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibilityDI1…DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logicPositive logic (source) (DI1…DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1…DI8), > 16 V (state 0), < 10 V (state 1)
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable current DQ-, DQ+: 30 V DC
Software-configurable current DQ-, DQ+: 100 mA
Sampling duration2 ms +/- 0.5 ms (DI1…DI4) – discrete input
5 ms +/- 1 ms (DI5, DI6) – discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
10 ms +/- 1 ms (AO1) – analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AO1, AO2: +/- 0.2 % for analog output
Relay output number3
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
IsolationBetween power and control terminals
Maximum output frequency500 kHz
Maximum input current19.8 A
Variable speed drive application selectionCompressor centrifugal Building – HVAC
Other application Food and beverage processing
Fan Mining mineral and metal
Pump Mining mineral and metal
Fan Oil and gas
Other application Water and waste water
Screw compressor Building – HVAC
Pump Food and beverage processing
Fan Food and beverage processing
Atomization Food and beverage processing
Electro submersible pump (ESP) Oil and gas
Water injection pump Oil and gas
Jet fuel pump Oil and gas
Compressor for refinery Oil and gas
Centrifuge pump Water and waste water
Positive displacement pump Water and waste water
Electro submersible pump (ESP) Water and waste water
Screw pump Water and waste water
Lobe compressor Water and waste water
Screw compressor Water and waste water
Compressor centrifugal Water and waste water
Fan Water and waste water
Conveyor Water and waste water
Mixer Water and waste water
Motor power range AC-37…11 kW at 380…440 V 3 phases
7…11 kW at 480…500 V 3 phases
Quantity per set1
Enclosure mountingWall mounted
Environment
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level56 dB conforming to 86/188/EEC
Power dissipation in WNatural convection: 51 W at 380 V, switching frequency 4 kHz
Forced convection: 255 W at 380 V, switching frequency 4 kHz
Volume of cooling air103 m3/h
operating positionVertical +/- 10 degree
Maximum THDI<48 % from 80…100 % of load conforming to IEC 61000-3-12
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…50 °C (without derating)
50…60 °C (with derating factor)
Ambient air temperature for storage-40…70 °C
Operating altitude<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
StandardsUL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Product certificationsATEX INERIS
CSA
UL
ATEX zone 2/22
DNV-GL
TÜV
MarkingCE
StandardsUL 508C
EN/IEC 61800-3
EN/IEC 61800-3 environment 1 category C2
EN/IEC 61800-3 environment 2 category C3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
noise level56 dB
Pollution degree2
Packing Units
Unit Type of Package 1Db
Number of Units in Package 11
Package 1 Height35 cm
Package 1 Width21.5 cm
Package 1 Length58 cm
Package 1 Weight10.467 kg
Unit Type of Package 2P06
Number of Units in Package 23
Package 2 Height75 cm
Package 2 Width60 cm
Package 2 Length80 cm
Package 2 Weight44.401 kg