Schneider ATV610C13N4

$ 3.018,00 Request exact price

Terms of sale:

  • Done Price Without Shipping:
    Our prices are listed without shipping costs. Shipping charges will be calculated and added during checkout based on your location and preferred shipping method.
  • Done Price Variability:
    Please note that prices are not fixed and may change due to factors such as market fluctuations, supplier costs, or promotional offers.
  • Done Worldwide Delivery:
    We offer delivery to almost any country worldwide. During checkout, you can select your country for shipping options and associated costs.
  • Check Mark These terms ensure transparency and flexibility in pricing and shipping options for our customers across the globe.
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
Category:

Description

Main
range of productEasy Altivar 610
Product or component typeVariable speed drive
Product specific applicationFan, pump, compressor, conveyor
Device short nameATV610
variantStandard version
Product destinationAsynchronous motors
Mounting modeCabinet mount
EMC filterIntegrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protectionIP20
Type of coolingForced convection
Supply frequency50…60 Hz +/-5 %
Network number of phases3 phases
[Us] rated supply voltage380…460 V – 15…10 %
Motor power kW132 kW for normal duty
110 kW for heavy duty
Motor power hp200 hp for normal duty
150 hp for heavy duty
Line current237 A at 380 V (normal duty)
203.8 A at 460 V (normal duty)
201 A at 380 V (heavy duty)
174.2 A at 460 V (heavy duty)
Prospective line Isc50 kA
Apparent power162.4 kVA at 460 V (normal duty)
138.7 kVA at 460 V (heavy duty)
Continuous output current250 A at 2.5 kHz for normal duty
211 A at 2.5 kHz for heavy duty
Maximum transient current275 A during 60 s (normal duty)
317 A during 60 s (heavy duty)
Asynchronous motor control profileVariable torque standard
Optimized torque mode
Constant torque standard
Output frequency0.0001…0.5 kHz
Nominal switching frequency2.5 kHz
Switching frequency1…8 kHz adjustable
number of preset speeds16 preset speeds
communication port protocolModbus serial
Option cardSlot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
Complementary
Output voltage<= power supply voltage
Motor slip compensationAutomatic whatever the load
Adjustable
Can be suppressed
Not available in permanent magnet motor law
Acceleration and deceleration rampsS, U or customized
Linear adjustable separately from 0.01 to 9000 s
Braking to standstillBy DC injection
Protection typeThermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Frequency resolutionDisplay unit: 0.1 Hz
Analog input: 0.012/50 Hz
Electrical connectionControl, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 70…3 x 120 mm²
Motor, screw terminal: 3 x 70…3 x 120 mm²
Connector type1 RJ45 (on the remote graphic terminal) for Modbus serial
Physical interface2-wire RS 485 for Modbus serial
Transmission frameRTU for Modbus serial
Transmission rate4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Type of polarizationNo impedance for Modbus serial
Number of addresses1…247 for Modbus serial
Method of accessSlave
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Local signalling2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Width300 mm
Height850 mm
1161 mm with IP21 conformity kit
Depth375 mm
Net weight85.5 kg
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
Discrete input number6
Discrete input typeDI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibilityDI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
Discrete input logicPositive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
Analogue output number2
Analogue output typeSoftware-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Sampling duration5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
Relay output number3
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
IsolationBetween power and control terminals
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Environment
Noise level76 dB conforming to 86/188/EEC
Power dissipation in W2755 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating positionVertical +/- 10 degree
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance6 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…45 °C (without derating)
45…60 °C (with derating factor)
Operating altitude<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
Environmental characteristicChemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
StandardsEN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
MarkingCE
Packing Units
Unit Type of Package 1Db
Number of Units in Package 11
Package 1 Height45.5 cm
Package 1 Width65.5 cm
Package 1 Length103.0 cm
Package 1 Weight99.0 kg