Schneider ATV32HU55N4
$ 477,00 Request exact price
Terms of sale:
- Price Without Shipping:
Our prices are listed without shipping costs. Shipping charges will be calculated and added during checkout based on your location and preferred shipping method. - Price Variability:
Please note that prices are not fixed and may change due to factors such as market fluctuations, supplier costs, or promotional offers. - Worldwide Delivery:
We offer delivery to almost any country worldwide. During checkout, you can select your country for shipping options and associated costs. - These terms ensure transparency and flexibility in pricing and shipping options for our customers across the globe.
Category: Schneider
Description
range of product | Altivar 32 |
---|---|
Product or component type | Variable speed drive |
Product destination | Synchronous motors Asynchronous motors |
Product specific application | Complex machines |
Function available | – |
Assembly style | With heat sink |
Component name | ATV32 |
EMC filter | Class C2 EMC filter integrated |
Network number of phases | 3 phases |
[Us] rated supply voltage | 380…500 V – 15…10 % |
Supply voltage limits | 323…550 V |
Supply frequency | 50…60 Hz – 5…5 % |
Network frequency | 47.5…63 Hz |
Motor power kW | 5.5 kW at 380…480 V |
Motor power hp | 7.5 hp at 380…480 V |
Line current | 14.5 A for 500 V 3 phases 5.5 kW / 7.5 hp 20.7 A for 380 V 3 phases 5.5 kW / 7.5 hp |
---|---|
Apparent power | 17.9 kVA at 500 V 3 phases 5.5 kW / 7.5 hp |
Prospective line Isc | 22 kA for 3 phases |
Nominal output current | 14.3 A at 4 kHz 500 V 5.5 kW / 7.5 hp |
Maximum transient current | 21.5 A for 60 s 5.5 kW / 7.5 hp |
Output frequency | 0.0005…0.599 kHz |
Nominal switching frequency | 4 kHz |
Switching frequency | 2…16 kHz adjustable |
Speed range | 1…100 for asynchronous motor in open-loop mode |
Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
Torque accuracy | +/- 15 % |
Transient overtorque | 170…200 % |
Braking torque | <= 170 % with braking resistor |
Asynchronous motor control profile | Flux vector control without sensor, standard Flux vector control without sensor – Energy Saving, NoLoad law Voltage/frequency ratio, 5 points Voltage/frequency ratio – Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points |
Synchronous motor control profile | Vector control without sensor |
Regulation loop | Adjustable PID regulator |
Motor slip compensation | Automatic whatever the load Adjustable 0…300 % Not available in voltage/frequency ratio (2 or 5 points) |
Local signalling | 1 LED red for drive voltage 1 LED green for CANopen run 1 LED red for CANopen error 1 LED red for drive fault |
Output voltage | <= power supply voltage |
Noise level | 43 dB conforming to 86/188/EEC |
Insulation | Electrical between power and control |
Electrical connection | Screw terminal, clamping capacity: 0.5…1.5 mm², AWG 18…AWG 14 (control) Removable screw terminals, clamping capacity: 2.5…16 mm², AWG 12…AWG 6 (motor/braking resistor) Screw terminal, clamping capacity: 4…16 mm², AWG 10…AWG 6 (power supply) |
Tightening torque | 0.5 N.m, 4.4 lb/ft (control) 1.2 N.m, 10.6 lb/ft (motor/braking resistor) 1.2 N.m, 10.6 lb/ft (power supply) |
Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
Analogue input number | 3 |
Analogue input type | AI1 voltage: 0…10 V DC, impedance: 30000 Ohm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30000 Ohm, resolution 10 bits AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
Sampling duration | 2 ms (AI1, AI2, AI3) – analog input(s) 2 ms (AO1) – analog input(s) |
Response time | LI1…LI6 8 ms, tolerance +/- 0.7 ms for logic output(s) R1A, R1B, R1C 2 ms for relay output(s) R2A, R2C 2 ms for relay output(s) |
Accuracy | +/- 0.2 % (AI1, AI2, AI3) for a temperature of -10…60 °C +/- 0.5 % (AI1, AI2, AI3) for a temperature of 25 °C +/- 1 % (AO1) for a temperature of 25 °C +/- 2 % (AO1) for a temperature of -10…60 °C |
Linearity error | +/- 0.2…0.5 % of maximum value (AI1, AI2, AI3) +/- 0.3 % (AO1) |
Analogue output number | 1 |
Analogue output type | AO1 software-configurable current 0…20 mA, impedance: 800 Ohm, resolution 10 bits AO1 software-configurable voltage 0…10 V, impedance: 470 Ohm, resolution 10 bits |
Discrete output number | 3 |
Discrete output type | Configurable relay logic: (R1A, R1B, R1C) NO/NC – 100000 cycles Configurable relay logic: (R2A, R2B) NO – 100000 cycles Logic: (LO) |
Minimum switching current | 5 mA at 24 V DC for configurable relay logic |
Maximum switching current | R1: 3 A at 250 V AC resistive load, cos phi = 1 R1: 4 A at 30 V DC resistive load, cos phi = 1 R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4 R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4 R2: 5 A at 250 V AC resistive load, cos phi = 1 R2: 5 A at 30 V DC resistive load, cos phi = 1 |
Discrete input number | 7 |
Discrete input type | Programmable (sink/source) (LI1…LI4)24…30 V DC, with level 1 PLC Programmable as pulse input 20 kpps (LI5)24…30 V DC, with level 1 PLC Switch-configurable PTC probe (LI6)24…30 V DC Safe torque off (STO)24…30 V DC – 1500 Ohm |
Discrete input logic | Negative logic (sink) (LI1…LI6), > 19 V (state 0), < 13 V (state 1) Positive logic (source) (LI1…LI6), < 5 V (state 0), > 11 V (state 1) |
Acceleration and deceleration ramps | Linear Ramp switching Deceleration ramp automatic stop DC injection CUS S U Deceleration ramp adaptation |
Braking to standstill | By DC injection |
Protection type | Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive |
communication port protocol | CANopen Modbus |
Connector type | 1 RJ45 (on front face) for Modbus/CANopen |
Physical interface | 2-wire RS 485 for Modbus |
Transmission frame | RTU for Modbus |
Type of polarization | No impedance for Modbus |
Number of addresses | 1…127 for CANopen 1…247 for Modbus |
Method of access | Slave CANopen |
Electromagnetic compatibility | 1.2/50 µs – 8/20 µs surge immunity test, level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test, level 3 conforming to IEC 61000-4-6 Electrical fast transient/burst immunity test, level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test, level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test, level 3 conforming to IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
Width | 150 mm |
Height | 308 mm |
Depth | 232 mm |
Net weight | 7.5 kg |
Option card | Communication card for CANopen daisy chain Communication card for CANopen open style Communication card for DeviceNet Communication card for EtherNet/IP Communication card for Profibus DP V1 |
Functionality | Mid |
Specific application | Other applications |
standards | EN/IEC 61800-5-1 EN 61800-3 environments 2 category C2 EN/IEC 61800-3 EN 55011 class A group 1 EN 61800-3 environments 1 category C2 |
---|---|
Product certifications | CSA UL GOST C-Tick NOM 117 |
Marking | CE |
Pollution degree | 2 conforming to EN/IEC 61800-5-1 |
IP degree of protection | IP20 conforming to EN/IEC 61800-5-1 |
Vibration resistance | 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
Ambient air temperature for operation | -10…50 °C without derating 50…60 °C with derating factor |
Ambient air temperature for storage | -25…70 °C |
Operating altitude | <= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m |
operating position | Vertical +/- 10 degree |
Warranty | 18 months |
---|