Schneider ATV312HU55N4
$ 683,00 Request exact price
Terms of sale:
- Price Without Shipping:
Our prices are listed without shipping costs. Shipping charges will be calculated and added during checkout based on your location and preferred shipping method. - Price Variability:
Please note that prices are not fixed and may change due to factors such as market fluctuations, supplier costs, or promotional offers. - Worldwide Delivery:
We offer delivery to almost any country worldwide. During checkout, you can select your country for shipping options and associated costs. - These terms ensure transparency and flexibility in pricing and shipping options for our customers across the globe.
Description
Main Features
Series
Altivar 312
Product Type
Frequency converter
Purpose of the product
Asynchronous electric motors
Special application area of the product
Simple machine
assembly style
With radiator
component name
ATV312
engine power, kW
5,5 kW
engine power, hp
7.5 hp
[Us] rated mains voltage
380…500 V – 15…10 %
power supply frequency
50…60 Hz – 5…5 %
Number of phases
3 phase
linear current
21.9 A at 380 V, Isc = 22 kA
16.5A to 500 V
interference filter
Built
-in full power
15 kVA
max. transient current
21.5 A for 60 S
power dissipation, W
232 W at rated load
speed range
1…50
Asynchronous electric branch control profile
Factory setting: constant torque
Sensorless vector motor control with auxiliary
electrical connection
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6 clamp 2.5 mm2 AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- clamp 16 mm2 AWG 6
power supply
Internal power supply for logic inputs: 19…30 V <100 mA, protection type: overload and short circuit protection
Internal power supply for the adjustment potentiometer: 10…10.8V <10 mA, protection type: overload and short circuit protection
Communication port protocol
Modbus
CANopen
Degree of protection IP
IP20 on the top Without a closing plate
IP21 on the connection terminals
IP31 on the top
IP41 on the top
is an optional card
Communication card for CANopen loop
Communication card for DeviceNet
Communication Card for Fipio
Communication card for Modbus TCP
Communication card for Profibus DP
Additional features
Supply voltage limits
323…550 mile
assumed linear Isc
22 kA
continuous output current
14.3A at 4 kHz
The output frequency
is 0…500 inches
nominal. switching frequency
4 kHz
switching frequency
2…16 kHz is adjustable.
transient torque overload
170…200 % of the rated torque of the engine
braking torque
150 % for 60 s with brake resistor
100% with brake resistor permanently
150 % without brake resistor
control loop
PI frequency controller
compensation of shaft slippage motor
Automatically at any load
Adjustable.
Suppressed
Output voltage
<= supply voltage
tightening torque
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6: 0.6 N·m
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 2.5 N·m
insulation
Between the power and control circuits
Number of analog inputs
3
Connection type
AI1 is set. voltage 0…10 V, input voltage 30 V max., impedance: 30000 ohms
AI2 is set. voltage +/- 10 V, input voltage 30 V max., impedance: 30000 ohms
AI3 set current 0…20 mA, impedance: 250 ohms
sampling duration
AI1, AI2, AI3: 8 ms Analog
LI1…LI6: 4 ms discrete
response time
AOV, AOC 8 ms for Analog
R1A, R1B, R1C, R2A, R2B 8 ms for discrete
linearization error
+/- 0.2 % for output
Number of analog outputs
1
type of analog output
AOC Set current: 0…20 mA, impedance: 800 ohms, resolution: 8 bits
Ask AOV. Voltage: 0…10 V, impedance: 470 ohms, resolution: 8 bits
type of digital inputs
The logic input is not connected (LI1…LI4), < 13 V (state 1)
Negative logic (“source”) (LI1…LI6), > 19 V (state 0)
Positive logic (source) (LI1…LI6), < 5 V (state 0), > 11 V (state 1)
Number of digital outputs
2
type of digital output
We ask. Relay logic: (R1A, R1B, R1C) 1 N.O. + 1 N.Z. – 100000 cycles
We ask. Relay logic: (R2A, R2B) N.Z. – 100000 cycles
minimum switching current
R1-R2 10 mA to 5 V post. current
max. switching current
R1-R2: 2 A in 250 V trans. the current is inductive. loading, cos phi = 0.4 and L/R = 7 ms
R1-R2: 2 A at 30 V post. the current is inductive. loading, cos phi = 0.4 and L/R = 7 ms
R1-R2: 5 A to 250 V trans. Current resistive loading, cos phi = 1 and L/R = 0 ms
R1-R2: 5 A at 30 V post. Current resistive loading, cos phi = 1 and L/R = 0 ms
Number of digital inputs
6
type of digital input
LI1…LI6) Programmable in 24 V, 0…100 mA for PLC, impedance: 3500 ohms
acceleration and deceleration programs
Linear, set separately, from 0.1 to 999.9 s
S, U or Po selected by the customer
braking to a stop
By applying direct current
type of protection
Phase disappearance at the input: drive
Protection circuits against high and low voltage l: drive
Protection function against significant voltage reduction: drive
Disappearance of engine phases: drive
Overcurrent between output phase and ground (only when on: drive
Overheating protection: drive
Short circuit between motor phases: drive
Thermal protection: motor
insulation resistance
>= 500 mOm 500 Per post. current for 1 minute
Local indication
Drive voltage: 1 LED (red)
CANopen bus status: four 7-segment
time constant displays
5 ms to change the reference value
frequency resolution
Analog input: 0.1…100 Hz
Display unit: 0.1Hz
Connector type
1 RJ45 for Modbus/CANopen
Physical interface
RS485 multipoint serial line
transmission frame
RTU
transfer rate
10, 20, 50, 125, 250, 500 Kbit/s or 1 Mbit/s for CANopen
4800, 9600 or 19200 bps for Modbus
number of addresses
1…127 for CANopen
1…247 for Modbus
number of drives
127 for CANopen
31 for Modbus
Marking
se
Working position
Vertical +/- 10 degrees
external dimension
442 x 239 x 192 mm
300 x 210 x 170 mm
232 x 180 x 170 mm
402 x 239 x 192 mm
Height
232 mm
Width
180 mm
Depth
172 mm
Net weight
6,5 kg
Operating conditions
Electrical insulation strength
2410 mile direct current between ground and power terminals
3400 mile Alternating current between control and power terminals
Electromagnetic compatibility
Immunity to pulse interference 1,2/50 µs – 8/20 mk level 3 in accordance with IEC 61000-4-5
Immunity test to switching devices level 4 in accordance with IEC 61000-4-4
Electrolytic discharge resistance test level 3 in accordance with IEC 61000-4-2
RF interference resistance test level 3 in accordance with IEC 61000-4-3
Standards
IEC 61800-5-1
IEC 61800-3
Certificates
gost
DNV
NOM
UL
CSA
C-Tick
Degree of contamination
2
Protective version
TC
Vibration resistance
1 gn (frequency= 13…150 inch) according to EN/IEC 60068-2-6
1.5 mm (frequency= 3…13 inches) in accordance with EN/IEC 60068-2-6
Impact resistance
15 gn for 11 ms in accordance with EN/IEC 60068-2-27
relative humidity
5…95% without condensation in accordance with IEC 60068-2-3
5…95% without dropping water droplets in accordance with IEC 60068-2-3
Ambient temperature during storage
-25…70 °C
operating ambient temperature
-10…50 °C Without deterioration of nominal values (with protective cover on top of the drive)
-10…60 °C with a reduction factor (without a protective cover on top of the drive)