Description
| range of product | Altivar 12 | 
|---|---|
| Product or component type | Variable speed drive | 
| Product specific application | Simple machine | 
| Mounting mode | Cabinet mount | 
| communication port protocol | Modbus | 
| Supply frequency | 50/60 Hz +/- 5 % | 
| [Us] rated supply voltage | 200…240 V – 15…10 % | 
| nominal output current | 3.5 A | 
| Motor power hp | 0.75 hp | 
| Motor power kW | 0.55 kW | 
| Motor power hp | 0.75 hp | 
| EMC filter | Integrated | 
| IP degree of protection | IP20 | 
| Discrete input number | 4 | 
|---|---|
| Discrete output number | 2 | 
| Analogue input number | 1 | 
| Analogue output number | 1 | 
| Relay output number | 1 | 
| physical interface | 2-wire RS 485 | 
| Connector type | 1 RJ45 | 
| Continuous output current | 3.5 A 4 kHz | 
| Method of access | Server Modbus serial | 
| Speed drive output frequency | 0.5…400 Hz | 
| Speed range | 1…20 | 
| Sampling duration | 20 ms +/- 1 ms logic input 10 ms analogue input | 
| Linearity error | +/- 0.3 % of maximum value analogue input | 
| Frequency resolution | Analog input converter A/D, 10 bits Display unit 0.1 Hz | 
| Time constant | 20 ms +/- 1 ms for reference change | 
| Transmission rate | 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s | 
| Transmission frame | RTU | 
| Number of addresses | 1…247 | 
| Data format | 8 bits, configurable odd, even or no parity | 
| Communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) | 
| type of polarization | No impedance | 
| 4 quadrant operation possible | False | 
| Asynchronous motor control profile | Voltage/frequency ratio (V/f) Quadratic voltage/frequency ratio Sensorless flux vector control | 
| Maximum output frequency | 4 kHz | 
| Transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor | 
| Acceleration and deceleration ramps | Linear from 0 to 999.9 s S U | 
| Motor slip compensation | Preset in factory Adjustable | 
| Switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor | 
| Nominal switching frequency | 4 kHz | 
| Braking to standstill | By DC injection | 
| Brake chopper integrated | False | 
| Line current | 8.0 A 100 V heavy duty) 6.7 A 120 V heavy duty) | 
| Maximum input current | 6.7 A | 
| Maximum output voltage | 240 V | 
| Apparent power | 1.6 kVA 240 V heavy duty) | 
| Maximum transient current | 5.3 A 60 s heavy duty) 5.8 A 2 s heavy duty) | 
| Network frequency | 50…60 Hz | 
| Relative symmetric network frequency tolerance | 5 % | 
| Prospective line Isc | 1 kA | 
| Base load current at high overload | 3.5 A | 
| Power dissipation in W | Natural 34.0 W | 
| With safety function Safely Limited Speed (SLS) | False | 
| With safety function Safe brake management (SBC/SBT) | False | 
| With safety function Safe Operating Stop (SOS) | False | 
| With safety function Safe Position (SP) | False | 
| With safety function Safe programmable logic | False | 
| With safety function Safe Speed Monitor (SSM) | False | 
| With safety function Safe Stop 1 (SS1) | False | 
| With sft fct Safe Stop 2 (SS2) | False | 
| With safety function Safe torque off (STO) | False | 
| With safety function Safely Limited Position (SLP) | False | 
| With safety function Safe Direction (SDI) | False | 
| Protection type | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t | 
| Tightening torque | 7.08 lbf.in (0.8 N.m) | 
| Insulation | Electrical between power and control | 
| Quantity per set | Set of 1 | 
| Width | 2.83 in (72 mm) | 
| Height | 5.63 in (143 mm) | 
| Depth | 5.17 in (131.2 mm) | 
| Net weight | 1.76 lb(US) (0.8 kg) | 
| Operating altitude | > 1000…2000 m with current derating 1 % per 100 m <= 1000 m without derating | 
|---|---|
| operating position | Vertical +/- 10 degree | 
| Product certifications | NOM CSA C-Tick UL GOST RCM KC | 
| Marking | CE | 
| standards | UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 | 
| Assembly style | With heat sink | 
| Electromagnetic compatibility | Electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 Surge immunity test level 3 EN/IEC 61000-4-5 Voltage dips and interruptions immunity test EN/IEC 61000-4-11 | 
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 | 
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms | 
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz | 
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz | 
| Overvoltage category | Class III | 
| Regulation loop | Adjustable PID regulator | 
| Electromagnetic emission | Radiated emissions environment 1 category C2 EN/IEC 61800-3 2…16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2…12 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <32.81 ft (10 m) Conducted emissions with additional EMC filter environment 1 category C1 EN/IEC 61800-3 4…12 kHz shielded motor cable <65.62 ft (20 m) Conducted emissions with additional EMC filter environment 1 category C2 EN/IEC 61800-3 4…12 kHz shielded motor cable <164.04 ft (50 m) Conducted emissions with additional EMC filter environment 2 category C3 EN/IEC 61800-3 4…12 kHz shielded motor cable <164.04 ft (50 m) | 
| Vibration resistance | 1 gn 13…200 Hz)EN/IEC 60068-2-6 1.5 mm peak to peak 3…13 Hz) – drive unmounted on symmetrical DIN rail – EN/IEC 60068-2-6 | 
| Shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 | 
| Relative humidity | 5…95 % without condensation IEC 60068-2-3 5…95 % without dripping water IEC 60068-2-3 | 
| noise level | 0 dB | 
| Pollution degree | 2 | 
| Ambient air transport temperature | -13…158 °F (-25…70 °C) | 
| Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating 104…140 °F (40…60 °C) with current derating 2.2 % per °C | 
| Ambient air temperature for storage | -13…158 °F (-25…70 °C) | 
| Unit Type of Package 1 | Db | 
|---|---|
| Number of Units in Package 1 | 1 | 
| Package 1 Height | 4.17 in (10.600 cm) | 
| Package 1 Width | 7.32 in (18.600 cm) | 
| Package 1 Length | 7.32 in (18.600 cm) | 
| Package 1 Weight | 2.46 lb(US) (1.117 kg) | 
| Unit Type of Package 2 | P06 | 
| Number of Units in Package 2 | 45 | 
| Package 2 Height | 28.94 in (73.500 cm) | 
| Package 2 Width | 23.62 in (60.000 cm) | 
| Package 2 Length | 31.50 in (80.000 cm) | 
| Package 2 Weight | 139.57 lb(US) (63.310 kg) | 