Schneider LTMR27EFM

$ 921,00 Request exact price

Terms of sale:

  • Done Price Without Shipping:
    Our prices are listed without shipping costs. Shipping charges will be calculated and added during checkout based on your location and preferred shipping method.
  • Done Price Variability:
    Please note that prices are not fixed and may change due to factors such as market fluctuations, supplier costs, or promotional offers.
  • Done Worldwide Delivery:
    We offer delivery to almost any country worldwide. During checkout, you can select your country for shipping options and associated costs.
  • Check Mark These terms ensure transparency and flexibility in pricing and shipping options for our customers across the globe.
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
Category:

Description

buy Schneider

Main
RangeTeSys
Product nameTeSys T
Device short nameLTMR
Product or component typeMotor controller
Device applicationEquipment monitoring and control
Measurement current1.35…27 A
[Us] rated supply voltage100…240 V AC 50/60 Hz
Current consumption8…62.8 mA
Supply voltage limits93.5…264 V AC
communication port protocolModbus TCP/EtherNet/IP
Bus typeEthernet IEEE 802.3 0…159 10…100 Mbit/s, RJ45 2 shielded twisted pairs
Complementary
[Ui] rated insulation voltage690 V EN/IEC 60947-1
690 V CSA C22.2 No 14
690 V UL 508
[Uimp] rated impulse withstand voltage4 kV supply, inputs and outputs EN/IEC 60947-4-1
6 kV current or voltage measurement circuit EN/IEC 60947-4-1
0.8 kV communication circuit EN/IEC 60947-4-1
Short-circuit withstand100 kA EN/IEC 60947-4-1
Associated fuse rating4 A gG output
0.5 A gG control circuit
Protection typePhase unbalance
Earth-leakage protection
Thermal protection
Reverse polarity protection
Power factor variation
Overload
Load fluctuation
Locked rotor
Thermal overload protection
Phase failure
Overload (long time)
Network and machine diagnosis typeEvent recording
Trip context information
Phase fault and earth fault trip counters
Trip history information
Waiting time after overload tripping
Fault recording
Remaining operating time before overload tripping
Starting current and time
Motor control command recording
Running hours counter/operating time
logic input number6
Input current3.1 mA 100 V
7.5 mA 240 V
Current state 0 guaranteedLogic input 0…40 V <= 15 mA 25 ms
Current state 1 guaranteedLogic input 79…264 V >= 2 mA 25 ms
maximum output switching frequency2 Hz
Load current5 A 250 V AC logic output
5 A 30 V DC logic output
Permissible power480 VA AC-15), Ie = 2 A, 500000 cycles output)
30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Maximum operating rate1800 cyc/h
Contacts type and composition1 NO + 1 NC fault signal
3 NO
Metering typeAverage current Iavg
Phase current I1, I2, I3 RMS
Imbalance current
Earth-fault current
Temperature
Measurement accuracy5…15 % earth fault current internal measurement
1 % voltage 100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
Overvoltage categoryIII
Connection pitch0.20 in (5.08 mm)
Connections – terminalsControl circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible with cable end
Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24…AWG 14)solid without cable end
Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24…AWG 14)flexible with cable end
Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24…AWG 14)solid without cable end
Tightening torqueControl circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
Pollution degree3
Electromagnetic compatibilityElectrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2)
Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3)
Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4)
Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11)
Conducted RF disturbances 10 V)EN/IEC 61000-4-6)
Surges 0.5 kV)EN/IEC 61000-4-5)
Surges 1 kV)EN/IEC 61000-4-5)
Surges 1 kV)EN/IEC 61000-4-5)
Surges 2 kV)EN/IEC 61000-4-5)
Surges 2 kV)EN/IEC 61000-4-5)
Surges 4 kV)EN/IEC 61000-4-5)
Surges 2 kV)EN/IEC 61000-4-5)
Width3.58 in (91 mm)
Height2.40 in (61 mm)
Depth4.82 in (122.5 mm)
Net weight1.17 lb(US) (0.53 kg)
web servicesWeb server
Compatibility codeLTMR
Environment
StandardsIACS E10
UL 508
IEC 60947-4-1
EN 60947-4-1
CSA C22.2 No 14
Product certificationsEAC
DNV
BV
C-Tick
CCC
ABS
RINA
RMRoS
CSA
NOM
LROS (Lloyds register of shipping)
UL
KERI
GL
ATEX
Protective treatment12 x 24 hour cycles EN/IEC 60068-2-30
48 h EN/IEC 60070-2-11
TH EN/IEC 60068
Fire resistance1202 °F (650 °C) EN/IEC 60695-2-12
1760 °F (960 °C) UL 94
Ambient air temperature for operation-4…140 °F (-20…60 °C)
Ambient air temperature for storage-40…176 °F (-40…80 °C)
Operating altitude<= 2000 m without derating
Mechanical robustnessVibrations mounted on symmetrical rail1 Gn, 5…300 Hz EN/IEC 60068-2-6
Vibrations plate mounted4 Gn, 5…300 Hz EN/IEC 60068-2-6
Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
IP degree of protectionIP20
Packing Units
Unit Type of Package 1Db
Number of Units in Package 11
Package 1 Height2.83 in (7.2 cm)
Package 1 Width3.94 in (10.0 cm)
Package 1 Length5.31 in (13.5 cm)
Package 1 Weight18.69 oz (530.0 g)
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height5.91 in (15.0 cm)
Package 2 Width11.81 in (30.0 cm)
Package 2 Length15.75 in (40.0 cm)
Package 2 Weight12.38 lb(US) (5.615 kg)
Contractual warranty
Warranty18 months