range of product | Altivar Machine ATV340 |
---|---|
Product or component type | Variable speed drive |
Product specific application | Machine |
variant | Standard version |
Mounting mode | Wall mount |
communication port protocol | EtherNet/IP Modbus TCP Modbus serial |
Option card | Communication module, PROFINET Communication module, DeviceNet Communication module, CANopen Communication module, EtherCAT |
Network number of phases | 3 phases |
Supply frequency | 50…60 Hz +/- 5 % |
[Us] rated supply voltage | 380…480 V – 15…10 % |
nominal output current | 106.0 A |
Motor power kW | 75 kW for normal duty 55 kW for heavy duty |
Motor power hp | 100 hp for normal duty 75 hp for heavy duty |
EMC filter | Class C3 EMC filter integrated |
IP degree of protection | IP20 |
Degree of protection | UL type 1 |
Discrete input number | 8 |
---|---|
Discrete input type | PTI safe torque off: 0…30 kHz, 24 V DC (30 V) DI1…DI5 programmable as pulse input, 24 V DC (30 V), impedance: 3.5 kOhm programmable |
number of preset speeds | 16 preset speeds |
Discrete output number | 1.0 |
Discrete output type | Programmable output DQ1, DQ2 30 V DC 100 mA |
Analogue input number | 3 |
Analogue input type | AI1 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI1 software-configurable temperature probe or water level sensor AI1 software-configurable voltage: 0…10 V DC, impedance: 31.5 kOhm, resolution 12 bits AI2 software-configurable voltage: – 10…10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
Analogue output number | 2 |
Analogue output type | Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0…20 mA impedance 500 Ohm, resolution 10 bits |
Relay output number | 3 |
Output voltage | <= power supply voltage |
Relay output type | Relay outputs R1A Relay outputs R1C electrical durability 100000 cycles Relay outputs R2A Relay outputs R2C electrical durability 100000 cycles |
Maximum switching current | Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Minimum switching current | Relay output R1B: 5 mA at 24 V DC Relay output R2C: 5 mA at 24 V DC |
physical interface | 2-wire RS 485 |
Connector type | 3 RJ45 |
Method of access | Slave Modbus RTU Slave Modbus TCP |
Transmission rate | 4.8 kbit/s 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity |
type of polarization | No impedance |
4 quadrant operation possible | True |
Asynchronous motor control profile | Variable torque standard Optimized torque mode Constant torque standard |
Synchronous motor control profile | Reluctance motor Permanent magnet motor |
Pollution degree | 2 conforming to EN/IEC 61800-5-1 |
Maximum output frequency | 0.599 kHz |
Acceleration and deceleration ramps | Linear adjustable separately from 0.01…9999 s S, U or customized |
Motor slip compensation | Not available in permanent magnet motor law Automatic whatever the load Can be suppressed Adjustable |
Switching frequency | 1…8 kHz adjustable 2.5…8 kHz with derating factor |
Nominal switching frequency | 2.5 kHz |
Braking to standstill | By DC injection |
Brake chopper integrated | True |
Line current | 131.3 A at 380 V (normal duty) 112.7 A at 480 V (normal duty) 98.9 A at 380 V (heavy duty) 86.9 A at 480 V (heavy duty) |
Line current | 131.3 A at 380 V with internal line choke (normal duty) 112.7 A at 480 V with internal line choke (normal duty) 98.9 A at 380 V with internal line choke (heavy duty) 86.9 A at 480 V with internal line choke (heavy duty) 98.9 A 86.9 A |
Maximum input current | 131.3 A |
Maximum output voltage | 480 V |
Apparent power | 93.7 kVA at 480 V (normal duty) 72.2 kVA at 480 V (heavy duty) |
Maximum transient current | 174 A during 60 s (normal duty) 159 A during 60 s (heavy duty) 174 A during 2 s (normal duty) 159 A during 2 s (heavy duty) |
Electrical connection | Screw terminal, clamping capacity: 0.75…1.5 mm² for control Screw terminal, clamping capacity: 70…120 mm² for DC bus Screw terminal, clamping capacity: 95…120 mm² for line side Screw terminal, clamping capacity: 95…120 mm² for motor |
Prospective line Isc | 50 kA |
Base load current at high overload | 106.0 A |
Base load current at low overload | 145.0 A |
Power dissipation in W | Natural convection: 115 W at 380 V, switching frequency 4 kHz (heavy duty) Forced convection: 917 W at 380 V, switching frequency 4 kHz (heavy duty) Natural convection: 158 W at 380 V, switching frequency 4 kHz (normal duty) Forced convection: 1359 W at 380 V, switching frequency 4 kHz (normal duty) |
Electrical connection | Control: screw terminal 0.75…1.5 mm²/AWG 18…AWG 16 DC bus: screw terminal 70…120 mm²/AWG 1/0…250 kcmil Line side: screw terminal 95…120 mm²/AWG 3/0…250 kcmil Motor: screw terminal 95…120 mm²/AWG 3/0…250 kcmil |
With safety function Safely Limited Speed (SLS) | True |
With safety function Safe brake management (SBC/SBT) | True |
With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | True |
With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | True |
With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False |
Protection type | Thermal protection: motor Safe torque off: motor Motor phase loss: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive Motor phase loss: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Exceeding limit speed: drive Break on the control circuit: drive |
Width | 271.0 mm |
Height | 908.0 mm |
Depth | 309.0 mm |
Net weight | 57.9 kg |
Continuous output current | 145 A at 4 kHz for normal duty 106 A at 4 kHz for heavy duty |
Operating altitude | <= 4800 m with current derating above 1000m |
---|---|
operating position | Vertical +/- 10 degree |
Product certifications | UL CSA TÜV EAC CTick |
Marking | CE |
standards | EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1 UL 508C IEC 61000-3-12 |
Maximum THDI | <48 % full load conforming to IEC 61000-3-12 <48 % 80 % load conforming to IEC 61000-3-12 |
Assembly style | With heat sink |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
Volume of cooling air | 295.0 m3/h |
Type of cooling | Forced convection |
Overvoltage category | Class III |
Regulation loop | Adjustable PID regulator |
noise level | 62.4 dB |
Pollution degree | 2 |
Ambient air transport temperature | -40…70 °C |
Ambient air temperature for operation | -15…50 °C without derating (vertical position) 50…60 °C with derating factor (vertical position) |
Ambient air temperature for storage | -40…70 °C |
Isolation | Between power and control terminals |
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 60 cm |
Package 1 Width | 43 cm |
Package 1 Length | 111 cm |
Package 1 Weight | 59 kg |