Description
range of product | Altivar 312 |
---|---|
Product or component type | Variable speed drive |
Product destination | Asynchronous motors |
Product specific application | Simple machine |
Assembly style | With heat sink |
Component name | ATV312 |
Motor power kW | 4 kW |
Motor power hp | 5 hp |
[Us] rated supply voltage | 380…500 V – 15…10 % |
Supply frequency | 50…60 Hz – 5…5 % |
Network number of phases | 3 phases |
Line current | 13.9 A 380 V, Isc = 5 kA 10.6 A 500 V |
EMC filter | Integrated |
Apparent power | 9.2 kVA |
Maximum transient current | 14.3 A 60 s |
Power dissipation in W | 150 W at nominal load |
Speed range | 1…50 |
Asynchronous motor control profile | Sensorless flux vector control with PWM type motor control signal Factory set : constant torque |
Electrical connection | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6 terminal 0.00 in² (2.5 mm²) AWG 14 L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 0.01 in² (5 mm²) AWG 10 |
Supply | Internal supply for logic inputs 19…30 V 100 mA overload and short-circuit protection Internal supply for reference potentiometer (2.2 to 10 kOhm) 10…10.8 V 10 mA overload and short-circuit protection |
communication port protocol | Modbus CANopen |
IP degree of protection | IP20 on upper part without cover plate IP21 on connection terminals IP31 on upper part IP41 on upper part |
Option card | Communication card CANopen daisy chain Communication card DeviceNet Communication card Fipio Communication card Modbus TCP Communication card Profibus DP |
Supply voltage limits | 323…550 V |
---|---|
Prospective line Isc | 5 kA |
Continuous output current | 9.5 A 4 kHz |
Output frequency | 0…500 Hz |
Nominal switching frequency | 4 kHz |
Switching frequency | 2…16 kHz adjustable |
Transient overtorque | 170…200 % of nominal motor torque |
Braking torque | 150 % 60 s with braking resistor 100 % with braking resistor continuously 150 % without braking resistor |
Regulation loop | Frequency PI regulator |
Motor slip compensation | Suppressable Automatic whatever the load Adjustable |
Output voltage | <= power supply voltage |
Tightening torque | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6 5.31 lbf.in (0.6 N.m) L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 10.62 lbf.in (1.2 N.m) |
Insulation | Electrical between power and control |
Analogue input number | 3 |
Analogue input type | AI1 configurable voltage 0…10 V 30 V max 30000 Ohm AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm AI3 configurable current 0…20 mA 250 Ohm |
Sampling duration | AI1, AI2, AI3 8 ms analog LI1…LI6 4 ms discrete |
Response time | AOV, AOC 8 ms analog R1A, R1B, R1C, R2A, R2B 8 ms discrete |
Linearity error | +/- 0.2 % output |
Analogue output number | 1 |
Analogue output type | AOC configurable current 0…20 mA 800 Ohm 8 bits AOV configurable voltage 0…10 V 470 Ohm 8 bits |
Discrete input logic | Logic input not wired LI1…LI4), < 13 V Negative logic (source) LI1…LI6), > 19 V Positive logic (source) LI1…LI6), < 5 V, > 11 V |
Discrete output number | 2 |
Discrete output type | Configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC – 100000 cycles Configurable relay logic R2A, R2B) NC – 100000 cycles |
Minimum switching current | R1-R2 10 mA 5 V DC |
Maximum switching current | R1-R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms R1-R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms R1-R2 5 A 250 V AC resistive, cos phi = 1 0 ms R1-R2 5 A 30 V DC resistive, cos phi = 1 0 ms |
Discrete input number | 6 |
Discrete input type | LI1…LI6) programmable 24 V, 0…100 mA PLC 3500 Ohm |
Acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.1 to 999.9 s |
Braking to standstill | By DC injection |
Protection type | Input phase breaks drive Line supply overvoltage and undervoltage safety circuits drive Line supply phase loss safety function, for three phases supply drive Motor phase breaks drive Overcurrent between output phases and earth (on power up only) drive Overheating protection drive Short-circuit between motor phases drive Thermal protection motor |
Insulation resistance | >= 500 mOhm 500 V DC for 1 minute |
Local signalling | Drive voltage 1 LED red) CANopen bus status four 7-segment display units |
Time constant | 5 ms for reference change |
Frequency resolution | Analog input 0.1…100 Hz Display unit 0.1 Hz |
Connector type | 1 RJ45 Modbus/CANopen |
physical interface | RS485 multidrop serial link |
Transmission frame | RTU |
Transmission rate | 10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen 4800, 9600 or 19200 bps Modbus |
Number of addresses | 1…127 CANopen 1…247 Modbus |
Number of drive | 127 CANopen 31 Modbus |
Marking | CE |
operating position | Vertical +/- 10 degree |
Outer dimension | 215 x 185 x 158 mm 184 x 140 x 150 mm 402 x 239 x 192 mm |
Height | 7.24 in (184 mm) |
Width | 5.59 in (142 mm) |
Depth | 5.98 in (152 mm) |
Net weight | 6.83 lb(US) (3.1 kg) |
Dielectric strength | 2410 V DC between earth and power terminals 3400 V AC between control and power terminals |
---|---|
Electromagnetic compatibility | 1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
standards | IEC 61800-3 IEC 61800-5-1 |
Product certifications | CSA C-Tick DNV NOM GOST UL |
Pollution degree | 2 |
Protective treatment | TC |
Vibration resistance | 1 gn 13…150 Hz)EN/IEC 60068-2-6 1.5 mm 3…13 Hz)EN/IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation IEC 60068-2-3 5…95 % without dripping water IEC 60068-2-3 |
Ambient air temperature for storage | -13…158 °F (-25…70 °C) |
Ambient air temperature for operation | 14…122 °F (-10…50 °C) without derating with protective cover on top of the drive) 14…140 °F (-10…60 °C) with derating factor without protective cover on top of the drive) |
Operating altitude | <= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m |
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 8.19 in (20.791 cm) |
Package 1 Width | 8.55 in (21.71 cm) |
Package 1 Length | 8.59 in (21.828 cm) |
Package 1 Weight | 6.95 lb(US) (3.151 kg) |
Unit Type of Package 2 | S06 |
Number of Units in Package 2 | 12 |
Package 2 Height | 28.94 in (73.5 cm) |
Package 2 Width | 23.62 in (60.0 cm) |
Package 2 Length | 31.50 in (80.0 cm) |
Package 2 Weight | 103.62 lb(US) (47.0 kg) |
Warranty | 18 months |
---|