Schneider ATV12H018M2
$ 74,00 Request exact price
Terms of sale:
- Price Without Shipping:
Our prices are listed without shipping costs. Shipping charges will be calculated and added during checkout based on your location and preferred shipping method. - Price Variability:
Please note that prices are not fixed and may change due to factors such as market fluctuations, supplier costs, or promotional offers. - Worldwide Delivery:
We offer delivery to almost any country worldwide. During checkout, you can select your country for shipping options and associated costs. - These terms ensure transparency and flexibility in pricing and shipping options for our customers across the globe.
Description
range of product | Altivar 12 |
---|---|
Product or component type | Variable speed drive |
Product specific application | Simple machine |
Mounting mode | Cabinet mount |
communication port protocol | Modbus |
Supply frequency | 50/60 Hz +/- 5 % |
[Us] rated supply voltage | 200…240 V – 15…10 % |
nominal output current | 1.4 A |
Motor power hp | 0.25 hp |
Motor power kW | 0.18 kW |
Motor power hp | 0.25 hp |
EMC filter | Integrated |
IP degree of protection | IP20 |
Discrete input number | 4 |
---|---|
Discrete output number | 2 |
Analogue input number | 1 |
Analogue output number | 1 |
Relay output number | 1 |
physical interface | 2-wire RS 485 |
Connector type | 1 RJ45 |
Continuous output current | 1.4 A at 4 kHz |
Method of access | Server Modbus serial |
Speed drive output frequency | 0.5…400 Hz |
Speed range | 1…20 |
Sampling duration | 20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input |
Linearity error | +/- 0.3 % of maximum value for analogue input |
Frequency resolution | Analog input: converter A/D, 10 bits Display unit: 0.1 Hz |
Time constant | 20 ms +/- 1 ms for reference change |
Transmission rate | 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity |
Communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
type of polarization | No impedance |
4 quadrant operation possible | False |
Asynchronous motor control profile | Voltage/frequency ratio (V/f) Sensorless flux vector control Quadratic voltage/frequency ratio |
Maximum output frequency | 4 kHz |
Transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor |
Acceleration and deceleration ramps | U Linear from 0 to 999.9 s S |
Motor slip compensation | Preset in factory Adjustable |
Switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor |
Nominal switching frequency | 4 kHz |
Braking to standstill | By DC injection |
Brake chopper integrated | False |
Line current | 3.4 A at 100 V (heavy duty) 2.8 A at 120 V (heavy duty) |
Maximum input current | 2.8 A |
Maximum output voltage | 240 V |
Apparent power | 0.7 kVA at 240 V (heavy duty) |
Maximum transient current | 2.1 A during 60 s (heavy duty) 2.3 A during 2 s (heavy duty) |
Network frequency | 50…60 Hz |
Relative symmetric network frequency tolerance | 5 % |
Prospective line Isc | 1 kA |
Base load current at high overload | 1.4 A |
Power dissipation in W | Natural: 18.0 W |
With safety function Safely Limited Speed (SLS) | False |
With safety function Safe brake management (SBC/SBT) | False |
With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | False |
With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | False |
With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False |
Protection type | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Tightening torque | 0.8 N.m |
Insulation | Electrical between power and control |
Quantity per set | Set of 1 |
Width | 72 mm |
Height | 143 mm |
Depth | 102.2 mm |
Net weight | 0.7 kg |
Operating altitude | > 1000…2000 m with current derating 1 % per 100 m <= 1000 m without derating |
---|---|
operating position | Vertical +/- 10 degree |
Product certifications | NOM CSA C-Tick UL GOST RCM KC |
Marking | CE |
standards | UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
Assembly style | On base plate |
Electromagnetic compatibility | Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
Overvoltage category | Class III |
Regulation loop | Adjustable PID regulator |
Electromagnetic emission | Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2…12 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m |
Vibration resistance | 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6 |
Shock resistance | 15 gn conforming to EN/IEC 60068-2-27 for 11 ms |
Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
noise level | 0 dB |
Pollution degree | 2 |
Ambient air transport temperature | -25…70 °C |
Ambient air temperature for operation | -10…40 °C without derating 40…60 °C with current derating 2.2 % per °C |
Ambient air temperature for storage | -25…70 °C |
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 12.000 cm |
Package 1 Width | 18.600 cm |
Package 1 Length | 19.500 cm |
Package 1 Weight | 895 g |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 45 |
Package 2 Height | 75.000 cm |
Package 2 Width | 60.000 cm |
Package 2 Length | 80.000 cm |
Package 2 Weight | 52.780 kg |
Warranty | 18 months |
---|